Phase Coupler
OVERVIEW / DOO-RT-PhCP-X 2+3
The DOO-RT-PhCp-2 and DOO-RT-PhCP-3 Phase couplers combine with a repeater are designed to couple the communication signals on different voltage lines of a power system.
The module is connected between the Repeater transceiver and the power lines, enabling the Coupling-Repeating functionality (see fig. below). Therefore, the communication signals are transmitted to and received from all connected lines.

APPLICATIONS
- Couples powerline communication signals across power voltages
- Designed to create contiguous powerline communication networks for flexible, smart automation systems for residential, commercial and industrial applications
FEATURES
- Provides three-phase coupling with a Repeater-transceiver module
- Can be used in split-single phase and three-phase power systems
- Includes protection against disturbances on the powerline
- Supplied with standard 12” x 12” x 4” metal enclosures
- Reliable powerline communication in high attenuation (0.5Ω min.) and noisy electrical environments
- LED indicators for Power, CPU, CFG and Tx/Rx
- FCC part 15 and Industry Canada ICES-006 compliant
- UL Pending
SPECIFICATIONS
- Operating voltage: 120-1,up 600-3 , 60Hz
- 262 kHz carrier frequency
- RX-TX, with always-on Repeating feature
- Ambient operating temperature: 0°C to +40°C
DIMENSIONS (resolution better on pdf)
CAUTIONS AND NOTES
The DOO-RT- PhCP -2 and DOO-RT- PhCP -3 must be installed beside the breaker panel.
Only used for junction boxes where min. 90°C wiring is used.
These devices are intended for installation in accordance with your local electric code and regulations. It is recommended that a qualified electrician perform this installation.
WIRING EXAMPLE

INSTALLATION INSTRUCTIONS
- Disconnect power at the circuit breaker before installation
- Open the electrical entrance cover and identify the Line, Neutral and Ground wires.
- Identify the conductor that supplies power to the load that you want to control.
- Attach the DOO-RT-PhCP-X beside the electrical compartment using the holes in the back of the enclosure.
- Connect L1, and N on a 240 volt electrical entrance and L1 L2, L3 and N in a 3 phases case to the coupler terminal
- Close the compartment cover and restore power.
ORDERING INFORMATION
Product number: DOO-RT- PhCP
· SPECIFY VOLTAGE AND NUMBER OF PHASES, WHEN ORDERING
|