Voltage Coupler

OVERVIEW / DOO-RT-VCP-2 and DOO-RT-VCP-3

The DOO-RT-VCP-2 and DOO-RT-VCP-3 Voltage couplers are designed to couple the communication signals on different voltage lines of a power system.

The module is connected between the Repeater transceiver and the power lines, enabling the Coupling-Repeating functionality (see fig. 1). Therefore, the communication signals are transmitted to and received from all connected lines.

The DOO-RT-VCP-2 and DOO-RT-VCP-3 can also be used as a passive coupler, when they are connected only to the power lines (fig. 2). In this case, the communication signals generated on one voltage pass to the other voltages.

DimOnOff® Inc. has designed electronic modules that allow you to create flexible, smart automation systems for residential, commercial and industrial buildings. Remote control & monitoring, automation, Energy savings, greater comfort and safety - are only a few benefits of the use of the DimOnOff® modules.

APPLICATIONS

  • Couples powerline communication signals across power voltages
  • Designed to create contiguous powerline communication networks for flexible, smart automation systems for residential, commercial and industrial applications

FEATURES

  • Can be used in split-single phase and three-phase power systems
  • Provides 2 operating modes: three-phase coupling module for transceivers in Repeat mode , or passive phase coupler
  • Includes protection against disturbances on the powerline
  • Supplied with standard 8" x 8" x 4" metal enclosures
  • Equipped with leads and mounting bracket for easy installation
  • Reliable powerline communication in high attenuation (0.5? min.) and noisy electrical environments
  • LED indicators for Power, CPU, CFG and Tx/Rx
  • FCC part 15 and Industry Canada ICES-006 compliant
  • UL Pending

SPECIFICATIONS

  • Operating voltage: 120,277, 347VAC, 60Hz
  • 262 kHz carrier frequency
  • Load power rating:
  • Can control up to 10 Amps of HID load- up to 347V
  • RX-TX, with user-selectable Repeating feature
  • Ambient operating temperature: 0°C to +40°C

•  SPECIFY VOLTAGE AND NUMBER OF PHASES, WHEN ORDERING

DIMENSIONS

CAUTIONS AND NOTES

  • The DOO-RT-VCP-2 and DOO-RT-VCP-3 must be installed into an electrical box with proper size.
  • Only used for junction boxes where min. 90°C wiring is used.
  • These devices are intended for installation in accordance with your local electric code and regulations. It is recommended that a qualified electrician perform this installation.

WIRING EXAMPLE

INSTALLATION INSTRUCTIONS

  • Disconnect power at the circuit breaker before installation
  • Open the electrical compartment and identify the Line, Neutral and Ground wires. Identify the conductor that supplies power to the load that you want to control.
  • Attach the DOO-RT-VCP-X inside the electrical compartment using the module mounting bracket. Connect the supply Ground wire (G) together with the module mounting bracket and the grounding screw.
  • Disconnect the Line wire that had supplied power to the load that you want to control.
  • Connect the disconnected wire of the fixture to the Blue lead of the DOO-RT-VCP-X.
  • Connect the supply Line wire (L) to the Black lead of the DOO-RT-VCP-X.
  • Connect the white lead of the DOO-RT-VCP-X together with the supply Neutral wire (N).
  • Place wires and module into the fixture .
  • Close the compartment cover and restore power.

ORDERING INFORMATION

Product number: DOO-RT-VCP

  SPECIFY VOLTAGE AND NUMBER OF PHASES, WHEN ORDERING

 
   