Voltage Coupler
OVERVIEW / DOO-RT-VCP-2 and DOO-RT-VCP-3
The DOO-RT-VCP-2 and DOO-RT-VCP-3 Voltage couplers are designed to couple the communication signals on different voltage lines of a power system.
The module is connected between the Repeater transceiver and the power lines, enabling the Coupling-Repeating functionality (see fig. 1). Therefore, the communication signals are transmitted to and received from all connected lines.
The DOO-RT-VCP-2 and DOO-RT-VCP-3 can also be used as a passive coupler, when they are connected only to the power lines (fig. 2). In this case, the communication signals generated on one voltage pass to the other voltages.
DimOnOff® Inc. has designed electronic modules that allow you to create flexible, smart automation systems for residential, commercial and industrial buildings. Remote control & monitoring, automation, Energy savings, greater comfort and safety - are only a few benefits of the use of the DimOnOff® modules.
APPLICATIONS
- Couples powerline communication signals across power voltages
- Designed to create contiguous powerline communication networks for flexible, smart automation systems for residential, commercial and industrial applications
FEATURES
- Can be used in split-single phase and three-phase power systems
- Provides 2 operating modes: three-phase coupling module for transceivers in Repeat mode , or passive phase coupler
- Includes protection against disturbances on the powerline
- Supplied with standard 8" x 8" x 4" metal enclosures
- Equipped with leads and mounting bracket for easy installation
- Reliable powerline communication in high attenuation (0.5? min.) and noisy electrical environments
- LED indicators for Power, CPU, CFG and Tx/Rx
- FCC part 15 and Industry Canada ICES-006 compliant
- UL Pending
SPECIFICATIONS
- Operating voltage: 120,277, 347VAC, 60Hz
- 262 kHz carrier frequency
- Load power rating:
- Can control up to 10 Amps of HID load- up to 347V
- RX-TX, with user-selectable Repeating feature
- Ambient operating temperature: 0°C to +40°C
SPECIFY VOLTAGE AND NUMBER OF PHASES, WHEN ORDERING
DIMENSIONS

CAUTIONS AND NOTES
- The DOO-RT-VCP-2 and DOO-RT-VCP-3 must be installed into an electrical box with proper size.
- Only used for junction boxes where min. 90°C wiring is used.
- These devices are intended for installation in accordance with your local electric code and regulations. It is recommended that a qualified electrician perform this installation.
WIRING EXAMPLE

INSTALLATION INSTRUCTIONS
- Disconnect power at the circuit breaker before installation
- Open the electrical compartment and identify the Line, Neutral and Ground wires. Identify the conductor that supplies power to the load that you want to control.
- Attach the DOO-RT-VCP-X inside the electrical compartment using the module mounting bracket. Connect the supply Ground wire (G) together with the module mounting bracket and the grounding screw.
- Disconnect the Line wire that had supplied power to the load that you want to control.
- Connect the disconnected wire of the fixture to the Blue lead of the DOO-RT-VCP-X.
- Connect the supply Line wire (L) to the Black lead of the DOO-RT-VCP-X.
- Connect the white lead of the DOO-RT-VCP-X together with the supply Neutral wire (N).
- Place wires and module into the fixture .
- Close the compartment cover and restore power.
ORDERING INFORMATION
Product number: DOO-RT-VCP
SPECIFY VOLTAGE AND NUMBER OF PHASES, WHEN ORDERING
|